Human Neutrophil Sorting Kit
Cell Sorts™ Human Neutrophil Sorting Kit (CS-0010) enriches untouched human neutrophils by column-free negative selection. The documented workflow starts with anticoagulated whole blood; density-gradient handling, red-cell lysis, and low-speed cleanup create a granulocyte-rich suspension. The supplied antibody cocktail and magnetic beads label non-neutrophil cells, while the target fraction remains unlabeled and is recovered by two controlled magnetic pour-offs.
For 1×107 prepared cells, the protocol specifies 10 µL antibody cocktail for 5 minutes, 8 µL magnetic beads for 5 minutes, and two 3-minute magnetic separations—an approximately 16-minute core selection after sample preparation. In one representative CD16-PE/CD66b-FITC plot, the double-positive quadrant increased from 75.0% to 98.4%; this is not a guaranteed specification. Verify identity, purity, viability, and function for each downstream assay. For research and in vitro cell-culture use only.
Product Features of the Human Neutrophil Sorting Kit
CS-0010 uses a documented column-free negative-selection workflow to enrich untouched human neutrophils from a granulocyte-rich suspension prepared from anticoagulated whole blood.
CS-0010 uses column-free negative selection to enrich an untouched human neutrophil fraction from a granulocyte-rich suspension prepared from anticoagulated whole blood. The listed core-selection steps total approximately 16 minutes; density-gradient processing, red-cell lysis, centrifugation, counting, transfers, and QC are additional.
How the Human Neutrophil Sorting Kit Works
Simple 4-step protocol for rapid cell isolation
Step 1: Prepare the Granulocyte-Rich Suspension
Process human anticoagulated whole blood by density-gradient separation, retain the granulocyte-containing red-cell layer, lyse red cells on ice for 15 minutes, complete the documented 500 × g and 120 × g centrifugation steps, and adjust to 5×10⁷ cells/mL.
Step 2: Label Non-Neutrophil Cells
Transfer 1×10⁷ prepared cells to a 5 mL flow tube, add 10 µL antibody cocktail, mix, and incubate at 2-8°C for 5 minutes.
Step 3: Bind Magnetic Beads
Add 8 µL thoroughly mixed magnetic beads, mix gently, incubate at 2-8°C for 5 minutes, then add 2 mL sorting buffer and mix by pipetting.
Step 4: Perform Two Magnetic Pour-Offs
Place the tube on a compatible 5 mL tube magnet for 3 minutes and pour the enriched suspension into a fresh tube. Repeat the 3-minute magnetic hold and controlled pour-off once more to collect the untouched target fraction.
Applications for the Human Neutrophil Sorting Kit
Potential downstream uses for the enriched untouched neutrophil fraction are listed below. Confirm identity, purity, viability, and functional suitability under laboratory-specific conditions.
The listed applications are potential research uses rather than guaranteed performance claims. Confirm post-sort identity, purity, viability, and functional suitability under laboratory-specific conditions.
Kit Components
CS-0010 includes the documented human neutrophil negative-selection antibody cocktail and magnetic beads for use with a prepared whole-blood granulocyte fraction.